EasyRA

easyraDescription: Lab technicians become experts with minimal training thanks to a simple and intuitive user interface. Four color-coded chapters guide the technician through all analyzer functions. The EasyRA analyzer is quickly operational and ready to run samples. Friendly displays clearly signal the progress of a run and easily allow changes. Analyze stat samples at any time with typical stat results in less than 8 minutes. Save valuable time by programming the next worklist while another worklist is running, or simply check reagent and cuvette inventories to prepare for the next run.
easyra2 Lab technicians become experts with minimal training thanks to a simple and intuitive user interface. Four color-coded chapters guide the technician through all analyzer functions. The EasyRA analyzer is quickly operational and ready to run samples. Friendly displays clearly signal the progress of a run and easily allow changes. Analyze stat samples at any time with typical stat results in less than 8 minutes. Save valuable time by programming the next worklist while another worklist is running, or simply check reagent and cuvette inventories to prepare for the next run.
easyra3 intentionally easy …to learn …to use …to maintain …to afford EasyRA® reagents are liquid, stable, and ready to use. The EasyRA analyzer automatically performs reagent parameter setup. Unlike barcodes, the new wireless RFID technology, located in each wedge label, contains all reagent information. Setup is fast, easy, and error-free. There is never a need for manual programming: simply place a smart reagent wedge on the analyzer and the EasyRA analyzer identifies reagent locations, number of samples remaining, sample volumes, and expiration dates, significantly reducing data entry errors. Two-way communication between the analyzer and the reagent wedges allows for continuous updating, providing real-time inventory control.
easyra4 The unique slide-out drawer makes maintaining the EasyRA analyzer simple by making all components easily accessible. Ion-selective electrodes and tubing are easily replaced. The “peek” position allows viewing of diluter and pumps during a sample run.
EasyRA specifications
system specifications true random access, clinical chemistry analyzer
throughput Patient results per hour, photometric: up to 120 tests/hour*; ISE: up to 240 tests/hour*; STAT time: 8 minutes (Na+/K+/Cl-/CO2/GLU/BUN/CREA)
types of analysis endpoint, enzymatic, rate, bichromatic, potentiometric, enzyme immunoassay (EIA), turbidometric immunoassay (TIA)
samples 24 sample positions per sample ring for patient, calibrator, or QC samples; STAT: up to 5 user-defined positions; optional second sample ring uniquely identified by analyzer; automatic dilution: 1:2, 1:3, 1:5 and 1:10 final dilution
sample volume photometric chemistries: 2.0–25.0 μL; programmed in 0.1 μL steps; ISE chemistries: serum: 80–90 μL; urine: 140 μL
sample containers sample cups or primary tubes in a wide range of sizes
sample identification position ID, barcode ID (optional), barcode types: codabar, code 39, 128, interleaved 2 of 5
reagents 24 positions for reagents; reagent cooling temperature 12º–15º C less than ambient; reagent identification: RFID (radio frequency identification) technology—automatic tracking and entry of reagent information (chemistry name, lot number, expiration date; reagent volumes; analysis volumes for reagents, samples, diluent; primary and secondary wavelengths; reaction read times; analysis type; reagent and sample blanking; linear range of assay; acceptable absorbance ranges). Reagents are ready to use. 6 open channels.
reagent volumes reagent volume (R1)/test 120–350 μL; programmed in 1 μL steps. reagent volume (R2)/test 10–50 μL; programmed in 1 μL steps
water supply reagent grade deionized water, diluent bottle
sampling system probe pre-heater; single probe with RF level sensing; inner and outer probe washing
cuvette material optical acrylic; disposable segments; 12 cuvettes per segment; 6 total segments in reaction area
reaction time 1–15 minutes
reaction temperature 37º ± 0.25º C (photometric chemistries)
wavelength 340, 405, 520, 550, 600, 660, 700; half bandwidth 10 ± 2 nm
light source xenon flash lamp, 5 year typical life
photometric linearity 0.0–2.5 Abs units for 0.6 cm pathlength (1% deviation)
photometric resolution 0.0001 Abs units at 1.0 Abs
quality control 2 levels of controls (Levey-Jennings plots for two levels)
calibration curves single and multilevel calibration (based on analyte)
user interface edit and monitor worklists; review results; review calibration and quality control results; Levey-Jennings charts for 31 days of QC results; on-board diagnostics and individual component monitoring; graphic instructions for daily, weekly and monthly maintenance procedures
data storage 2000 patient results; 56,000 test results, ability to archive and retrieve results
power requirements 100 VAC–240 VAC ± 10% 50–60 Hz, 4.0/2.0A
size and weight 40˝ w x 15˝ h x 26˝ d (102 cm x 38 cm x 66 cm), 88 lbs (40 kgs) without reagents
ambient conditions 15º–30º C (59º–86º F); <85% relative humidity, non-condensing atmospheric air environment
computer requirements minimum: Windows® 7**; CD/CD-RW; 1 RS-232 or USB port; touch screen monitor or SVGA color monitor, mouse and keyboard
printing local or network printer
optional feature ISE Module
* Actual tests per hour may vary.
** Windows is a registered trademark of Microsoft Corporation.

  Test Menu  
Routine Chemistry Enzyme Assays Cardiac Risk
Albumin Alkaline Phosphatase HDL – Direct
Bilirubin – Direct Alanine Aminotranferase LDL – Direct
Bilirubin – Total Amylase Triglycerides
Calcium Aspartate Aminotransferase Cholesterol
Creatinine Creatine Kinase  
Glucose Gamma-Glutamyl Diabetic Monitoring
Inorganic Phosphorous Transferase HbA1c
Magnesium Lactate Dehydrogenase Microalbumin
Total Protein Lipase  
Urea Nitrogen (BUN)   Urine Chemistry
Uric Acid Electrolytes Creatinine
  CO2 Sodium
Other Tests Sodium Potassium
CK-MB Potassium Chloride
CRP Chloride  
Li+   Calculated Tests/Ratios
  Specific Proteins Anion Gap
Anemia Assays IgG* BUN/Crea Ratio
Iron IgA* cLDL
TIBC IGM* eGFR
     
     
  *in development  
easyra
     
Reagent Kits   Cat. No Kit Size
(R1/R2/R3)
Tests/
Kit
Tests/
Wedge
On-Board
Stability
(days)
Calibration
Frequency
(days)
ALB Albumin 10218-4 4 x 39 mL 972 243 60 30
ALP Alkaline Phosphatase 10214-4 4 x 20 mL/4 mL 400 100 8
ALT (SGPT) Alanine Aminotransferase 10205-4 4 x 31 mL/8 mL 800 200 44
AMY Amylase 10217-4 4 x 39 mL 972 243 30
AST (SGOT) Aspartate
Aminotransferase
10206-4 4 x 31 mL/8 mL 844 211 44
BUN Blood Urea Nitrogen 10202-4 4 x 39 mL 780 195 60 7
CA Calcium 10210-4 4 x 29 mL/9 mL 328 82 21 14
CHOL Cholesterol 10204-4 4 x 39 mL 864 216 60 30
CK Creatine Kinase 10222-4 4 X 23 mL/6 mL 716 179 60
CKMB Creatine Kinase-MB 10226-4 4 x 28 mL/7 mL 700 175 30
CRP C-Reactive Protein 10228-4 4 x 9 mL/9 mL 400 100 61 61
CO2 Carbon Dioxide 10209-4 4 x 29 mL 340 85 10 10
CREA Creatinine 10203-4 4 x 29 mL/10 mL 644 161 60 20
CREA-U Urine Creatinine 10260-4 4 x 29 mL/10 mL 644 161 60 20
DBIL Direct Bilirubin 10212-4 4 x 29 mL/8 mL 724 181 30 28
GGT Gamma – Glutamyl 10219-4 4 x 29 mL/7 mL 876 219 60
GLU-H Glucose Hexokinase 10200-4 2 x 27 mL/6 mL 488 122 60 28
GLU-T Glucose Trinder 10201-4 4 x 39 mL 708 177 60 30
HbA1c Hemoglobin A1c 10230-2 2 x 30 mL/10 mL/7 mL 500 250 60 31
HDL HDL Cholesterol 10211-4 4 x 29 mL/10 mL 464 116 60 30
FE Iron 10223-4 4 x 19 mL/5 mL 504 126 26 26
LDH Lactate Dehydrogenase 10215-4 4 X 29 mL/8 mL 876 219 60
LDL LDL Cholesterol 10224-4 4 x 29 mL/10 mL 464 116 60 30
LIP Lipase 10227-4 4 x 20 mL/10 mL 400 100 60 14
MG Magnesium 10220-4 4 x 29 mL/9 mL 644 161 17 3
PHOS Phosphorus 10221-4 4 x 29 mL/6 mL 696 174 30 30
TBIL Total Bilirubin 10207-4 4 x 29 mL/8 mL 772 193 28 7
TIBC Total Iron Binding Capacity 10229-4 4 x 20 mL/6 mL 400 100 21 21
TP Total Protein 10213-4 4 x 24 mL 640 160 60 28
TRIG Triglycerides 10216-4 4 x 37 mL 776 194 30 30
uALB MicroAlbumin 10225-4 4 x 29 mL/8 mL 772 193 31 31
URIC Uric Acid 10208-4 4 x 39 mL 780 195 21 30
               

What to look for in remedies online? For example Temovate cream is a topical corticosteroid. This medicament reduce swelling associated with numerous skin problems. There are remedies betrothed only for them. If you are considering Viagra in Nova Scotia, you perhaps want to study about Viagra in Saskatchewan. What do you have to study about Kamagra Next Day Delivery? More info about Kamagra available at Viagra in Manitoba. Also known as impotence is defined as the impossibility to maintain an hard-on suitable for intercourse. In effect, a scientific reviews found that up to half of folk on such medication experience erectile dysfunction. What is the most vital facts you probably think regard about this? Online pharmacist services are the only safe variant if you are going to buy medications, like Kamagra, online.